DC Electric Full-size RTs
December 2007 Page 31
TM
Section 2 - Operation Function Tests
2.9 Function Tests
Function tests are designed to discover any malfunctions
before aerial platform is put into service. The operator
must understand and follow step-by-step instructions
to test all aerial platform functions.
IMPORTANT
Never use a malfunctioning aerial
platform. If malfunctions are discovered,
aerial platform must be tagged and
placed out of service. Repairs to aerial
platform may only be made by a qualified
service technician.
After repairs are completed, operator must perform a
pre-operation inspection and a series of function tests
again before putting aerial platform into service.
Prior to performing function tests, be sure to read and
understand Section 2.10 - Start Operation.
2.9-1 Test Battery Connectors
1. In battery roll-out tray, disconnect battery
connectors.
Result: Aerial platform functions should not
operate.
2.9-2 Base Control Console
WARNING
Ensure that you maintain three points of
contact when using the ladder to mount/
dismount platform.
1. Use the ladder of aerial platform to access
platform.
2. Close the gate.
3. On platform control console, pull out
emergency stop button.
4. Insert key into base/off/platform key switch
and select “
” base position.
5. Use the ladder to dismount from platform.
6. On base control console, select
” base
position.
7. On battery roll-out tray, ensure battery
connectors are properly connected.
Battery Connectors
Emergency Stop Button
Base/Platform
Switch
Raise/Lower
Switch