DC Electric Full-size RTs
December 2007 Page 59
TM
Section 2 - Operation Tables
Floor Loading Pressure
Length
Width
Width
Length
Length
Width
Diameter
Locally Concentrated Pressure (LCP): Overall Uniform Pressure (OUP):
Foot Print Area = Length x Width
=πr
2
Base Area = Length x Width
LCP =
Weight of Aerial Platform + Capacity
Foot Print Area x 4 (Tires)
OUP =
Weight of Aerial Platform + Capacity
Base Area