Page #30 background imageLoading...
Page #30 background image
213211AAA SJ63 AJ+
32
Section 3 – Familiarization Features and devices
FAMILIARIZATION
3.4-7 Overload status
Mode/Condition
Indicator
Light
Zone
Border
Light
Audible
Alarm
Drive
Functions
Powered
Boom
Functions
Emergency
Power
(Platform)
Emergency
Power
(Base)
The platform is near the rated load On Off Off Enabled Enabled Enabled Enabled
In the lowered travel position: the load
on the platform is more than the rated load
Flashing Off Pulsing Enabled Enabled Enabled Enabled
In the elevated travel position: the load
on the platform is more than the rated load
Flashing Off Pulsing Disabled Disabled Enabled Enabled
In the elevated travel position and
the boom is extended or the boom is
lowered to the border between the high
and low capacity zones:
the load on the platform is more than the
rated load for the low capacity zone. *
Off On Off Enabled
Boom raise
and Boom
retract only
Enabled Enabled
1885AA
* If you reset power to the controls (for example, push and pull the emergency-stop button) when the
MEWP is in this mode, the MEWP will be in the overload condition when elevated.
IMPORTANT
Movement into the low-capacity zone occurs
when the boom is in a position where it is
raised less than 55 degrees and extended
1.4 m (4.6 ft). Refer to Figure 03 and
Figure 04.
WARNING
Movement into the low-capacity zone is restricted
if the platform capacity is more than the
low-capacity zone platform capacity.
WARNING
If the platform load sensing system is in the fault
mode, the capacity zone lights ash alternately
and the overload light ashes. The capacity zone
border light continuously illuminates as well. Do
the steps that follow:
Make sure the platform is level, and there are
no obstructions in contact with the platform.
If the platform load sensing system stays in
the fault mode, the emergency-power unit
can be used to lower the platform. Remove
the MEWP for servicing. Speak to a qualied
service technician for repairs. If you do not
obey, there is a risk of death or serious injury.
High-
capacity
zone
Low-capacity
zone
Border
between the
high and low-
capacity zones
2.44 m
(8 ft)
10.74 m
(35 ft)
55°
Figure 03 High and low-capacity zones
(4.6 ft)
1.4 m
Figure 04 Fly boom extension into the low-capacity
zone
To order go to Discount-Equipment.com

Table of Contents

Other manuals for Skyjack SJ63 AJ+

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ63 AJ+ and is the answer not in the manual?

Skyjack SJ63 AJ+ Specifications

General IconGeneral
BrandSkyjack
ModelSJ63 AJ+
CategoryBoom Lifts
LanguageEnglish

Related product manuals