47
SJ9233 RT, SJ9243 RT, SJ9253 RT 221491AAA
Function tests Section 4 – Inspections Before Operation
4.3-2 Do a test of the control module and
load sensing module self-check
1. Push the emergency-stop button
2
on the
base control console.
1. Turn the main power disconnect switch
1
to
the on position.
2. Pull the emergency-stop button
2
on the base
control console.
▪
Result: The beeper makes a sound for
approximately 1 second. The light on the
emergency-stop button comes on. This shows
that the system is in operation, and there are
no faults.
3. Make sure there are no error codes on the
Skycoded™ display panel
5
.
▪
Result: If you see an error code, lock and tag
the MEWP. Remove the MEWP for servicing.
Speak to a qualified service technician for
repairs.
4.3-3 Do a test of the emergency-stop
button on the base
1. Turn the main power disconnect switch
1
to
the on position.
2. Pull the emergency-stop button
2
.
3. Start the engine at the base. Refer to Figure 06.
4. Push the emergency-stop button
2
.
▪
Result: The engine stops.
TM
2
5
1