EasyManua.ls Logo

Skyjack SJ9253 RT - Do a Test of the Control Module and Load Sensing Module Self-Check; Do a Test of the Emergency-Stop Button on the Base

Skyjack SJ9253 RT
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
47
SJ9233 RT, SJ9243 RT, SJ9253 RT 221491AAA
Function tests Section 4 – Inspections Before Operation
4.3-2 Do a test of the control module and
load sensing module self-check
1. Push the emergency-stop button
2
on the
base control console.
1. Turn the main power disconnect switch
1
to
the on position.
2. Pull the emergency-stop button
2
on the base
control console.
Result: The beeper makes a sound for
approximately 1 second. The light on the
emergency-stop button comes on. This shows
that the system is in operation, and there are
no faults.
3. Make sure there are no error codes on the
Skycoded™ display panel
5
.
Result: If you see an error code, lock and tag
the MEWP. Remove the MEWP for servicing.
Speak to a qualified service technician for
repairs.
4.3-3 Do a test of the emergency-stop
button on the base
1. Turn the main power disconnect switch
1
to
the on position.
2. Pull the emergency-stop button
2
.
3. Start the engine at the base. Refer to Figure 06.
4. Push the emergency-stop button
2
.
Result: The engine stops.
TM
2
5
1

Table of Contents