55
SJ9233 RT, SJ9243 RT, SJ9253 RT 221491AAA
Function tests Section 4 – Inspections Before Operation
WARNING
Look for overhead obstructions or other possible
hazards around the MEWP when you raise the
platform. Do not lower the platform unless the area
below is clear of personnel and obstructions. If
you do not obey, there is a risk of death or serious
injury.
5. Raise the platform by approximately 0.3 m (1 ft).
▪
Result: The platform raises.
6. Fully lower the platform.
▪
Result: The platform fully lowers.
7. Move the auto-level/differential lock switch
8
to the auto-level position
8a
.
8. Squeeze the function-enable switch
4
and pull
the controller handle
5
to fully retract all four
outriggers.
▪
Result: All four outriggers fully retract.
4.3-19 Do a test of the generator (optional
equipment)
1. Use the MEWP ladder to enter the platform.
2. Start the engine. Refer to Figure 06.
3. Move the generator switch
9
to the on
position.
▪
Result: The engine speed automatically
changes to high throttle. The generator starts.
The light goes on.
4. Move the generator switch
9
to the off position.
▪
Result: The generator stops. The light goes off.
The throttle goes back to idle.
TM
4
5
3
3b
8a
8
8b
9