Start and stop the generator (optional equipment) Section 5 – Operation
4. Ensure each outrigger pad is in firm contact over
its entire surface area, with a suitable supporting
surface.
NOTE
The drive functions are disabled if the outriggers are
not fully retracted.
CAUTION
If the outrigger alarm makes a sound during
operation, immediately lower the platform and put
the MEWP on a firm surface. The MEWP must be
on a firm surface for you to operate it.
Retract the outriggers
1. Fully lower the platform.
2. Move the auto-level/differential lock switch to
the auto-level position.
3. Squeeze the function-enable switch and
pull the controller handle to retract all four
outriggers. The light of the level indicator shows
the auto-level outrigger condition. Refer to
Figure 08.
IMPORTANT
Limit switches prevent outrigger damage. If the
drive functions are not available, do a visual
inspection of the outriggers to make sure they are
all fully retracted.
5.10 Start and stop the
generator (optional
equipment)
1. Start the engine. Refer to Figure 07.
2. Move the lift/off/drive switch to the lift position.
3. Move the generator switch to the on position to
start the generator.
4. Move the generator switch to the off position to
stop the generator.
NOTE
The generator stops in these situations:
You start the drive, lift, or auto-level functions
You push the emergency-stop button
You change the off/base/platform key switch
position
The engine stalls.