11 Operating Data and Parameters
SMA Solar Technology AG
User Manual 123SCCPXT-E7-BA-en-58
Name Description Value/range Explanation Default
value
Qmax** Limitation of reactive
power
0kVAr to 245kVAr SunnyCentral500CPXT 245kVAr
0kVAr to 310kVAr SunnyCentral630CPXT 310kVAr
0kVAr to 346kVAr SunnyCentral720CPXT 346kVAr
0kVAr to 365kVAr SunnyCentral760CPXT 365kVAr
0kVAr to 385kVAr SunnyCentral800CPXT 385kVAr
0kVAr to 409kVAr SunnyCentral850CPXT 409kVAr
0kVAr to 433kVAr SunnyCentral900CPXT 433kVAr
0kVAr to 485kVAr SunnyCentral1000CPXT 485kVAr
QoDQmax* Limitation of reactive
power in the operating
state "QatNight".
The reactive power can-
not exceed Qlimit.
0kVAr to 165kVAr SunnyCentral500CPXT 165kVAr
0kVAr to 210kVAr SunnyCentral630CPXT 210kVAr
0kVAr to 238kVAr SunnyCentral720CPXT 238kVAr
0kVAr to 251kVAr SunnyCentral760CPXT 251kVAr
0kVAr to 264kVAr SunnyCentral800CPXT 264kVAr
0kVAr to 281kVAr SunnyCentral850CPXT 281kVAr
0kVAr to 297kVAr SunnyCentral900CPXT 297kVAr
0kVAr to 330kVAr SunnyCentral1000CPXT 330kVAr
QEnsure* Guaranteed reactive
power
0kVAr to 245kVAr SunnyCentral500CPXT 0kVAr
0kVAr to 310kVAr SunnyCentral630CPXT
0kVAr to 346kVAr SunnyCentral720CPXT
0kVAr to 365kVAr SunnyCentral760CPXT
0kVAr to 385kVAr SunnyCentral800CPXT
0kVAr to 409kVAr SunnyCentral850CPXT
0kVAr to 433kVAr SunnyCentral900CPXT
0kVAr to 485kVAr SunnyCentral1000CPXT
PFAbsMin* Limitation of the displace-
ment power factor cosφ
0.5 … 1 0.9