12
Advanced Setting Menu
SETTING DESCRIPTION RANGE DEFAULT NOTE
000 Hardware Version N/A 3.1
001 Firmware Version N/A 3.4
002 Temperature - Room -10°C - 10°C -2.5°C 1
003 Temperature - Roof Cavity -10°C - 10°C 0°C 1
004 Screen Brightness - Maximum 0 - 100% 80%
005 Screen Brightness - Minimum 0 - 100% 20%
006 Boost Time 0 min – 60 min 20 min
007 Recycle Enable 0 - 1 1 1 = enabled
008 Recycle Speed 0 - 100% 0%
009 Recycle Temperature - Maximum Recycle Min. Temp - 50°C 30°C 2
010 Recycle Temperature - Minimum 0°C - Recycle Max. Temp 5°C 2
011 Temperature Set - Threshold 0°C - 5°C 1.5°C
012 Temperature Set - Differential 0°C - 20°C 5°C
013 Reserved N/A N/A
014 Reserved N/A N/A
015 Dew Point - Start -5°C - 5°C 0°C
016 Dew Point - Control Level 0 - 5 1
017 Filter Used Percentage 0 – 100% 0%
018 Filter Reset 0 - 100 0 3
1. If your roof cavity or room temperature readings are inaccurate, use these settings to calibrate them.
2. If RECYCLE
is enabled and the roof cavity sensor reading goes above the maximum recyle temperature setting or goes below the minimum recycle
temperature setting, then recycle mode will activate.
3. To reset the filter change 018 setting value to 10 and press SELECT
.