25
Recycle
This feature is designed for environments where extremes of temperature are
common. When your system is in VENTILATION AUTO Mode and the
roof temperature goes above the Maximum Roof Temperature (30ºC) setting,
or goes below the Minimum Roof Temperature (5ºC) setting, your SmartVent
system will limit the amount of air entering your home.
If you have a HEAT TRANSFER
kit installed, you can set the RECYCLE
speed in the Recycle setting.
RECYCLE
is your fan speed when your system is recycling indoor air.
Default RECYCLE time = 5 min on Low Speed 55 min OFF.
You can adjust the 55 min period to be either OFF, Low, Med or High fan speed.
1) The recycle setting is a feature available when a heat transfer kit is installed.
For more information about SmartVent system enhancements, contact 0800 140 150 or email enquiry@smartvent.co.nz