●Product individual parameters (continued)
Index
Sub
index
Access
∗1
Parameter
Data
type
∗2
Initial
value
Data
storage
∗3
Set value
∗4
Remarks
dec hex
7000
0x1B58
0 W
Communication OUT
output test
OUT Test
U8 - N
0: Normal output
1: Fixed output
The PD becomes 1 when a fixed
output has been received.
7010
0x1B62
0 W
Toggle
(Toggle output)
U8 - N
0: Measured value
16: OUT1
17: OUT2
80: Analogue output
224: Diagnostic bit
255: Error bit
Connected with hardware output
7100
0x1BBC
0 R
Analogue output
value
U8 0 Y
Voltage output:
0.1V increments
Current output:
1mA increments
8000
0x1F40
0 R
PD a
F32 - N
and intercept".
(page 79)
8010
0x1F4A
0 R
Flow rate PD
intercept b
F32 - N
and intercept".
(page 79)
8020
0x1F54
0 R
Flow peak value
S16 0 N
-200 to 4200
The conversion method from the
communication value to the actual
measurement value is the same as
the method for process data.
8030
0x1F5E
0 R
Flow bottom value
S16 0 N
8040
∗5
0x1F68
1 R
Accumulated
mantissa
F32 - N 0 to 9999
Accumulated PD × Accumulated
value conversion factor
= Current accumulated flow value
2 R
Accumulated index
F32 - N 0 to 6
∗1: "R" means Read and "W" means Write.
∗2: Refer to the table below for the symbol.
Symbol
Data type
(IO-Link standard)
Data length
Bit [byte]
Description
U8
UIntegerT
8 [1]
Unsigned integer
U16 16 [2]
S16
16 [2]
F32
32 [4]
C32
StringT
32 [4]
String
∗3: "Y" indicates that the parameter setting data is saved to the master, and "N" indicates that the parameter is not saved.
∗4: Read/write to un-selectable items will be rejected depending on the product No.
∗5: Individual access to the subindex is prohibited.
Set the subindex to "0 (batch access)" for reading or writing the data.