-93-
No.PF※※-OMZ0002
Specifications
Fluid
Applicable fluid
Air, N
2
(Air quality: ISO8573-1 1.1.2 to 1.6.2)
o
Flow
Set flow
rate
Instantaneous flow 5 to 525 L/min 10 to 1050 L/min 20 to 2100 L/min
Accumulated flow 0 to 999,999,990 L
Min.
unit
Instantaneous flow 1 L/min
Accumulated flow 10 L
Accumulated volume per pulse
(Pulse width = 50 msec.)
1 L/pulse 10 L/pulse
∗1
Select from 2 minutes or 5 minutes
Refer to the pressure loss graph
∗2
±5%F.S. (0 to 0.8 MPa, 0.6 MPa standard)
age
Used as switch output
device
12 to 24 VDC ±10%
±1%F.S. (±2%F.S. when response time is set to 0.05 second)
Temperature characteristics
o
o
Switch output
Select from NPN or PNP open collector output
Output mode
Select from Hysteresis mode, Window comparator mode,
Accumulated output mode, Accumulated pulse output mode,
Error output or Switch OFF
Switch operation Select from Normal output or Reversed output
Internal voltage drop
(Residual voltage)
1.5 V or less (Load current 80 mA)
Digital filter
∗3
Select from 0.05 s, 0.5 s, 0.15 s, 1.0 s, 2.0 s or 5.0 s
∗4
Delay time
∗5
3.4 ms or less
Variable at 0 to 60 s/0.01 step