Viewing and Clearing Wrench Cycle Counter
Each time torque or angle target is reached, wrench cycle counter is incremented. Maximum
cycle count is 999999.
1. From target torque or angle screen, press and hold ENTER button for 3 seconds.
2. Highlight CYCLE COUNT menu selection using UP/DOWN buttons.
3. Press ENTER button to display CYCLE COUNT screen.
4. To exit CYCLE COUNT screen without clearing count, press ENTER button while EXIT menu
selection is highlighted.
5. To reset wrench cycle count to 0, highlight CLEAR menu selection then press ENTER button.
6. EXIT menu selection is automatically highlighted after count is cleared. Press ENTER button
to return to main menu.
Note: If wrench is Locked (see Preset Lock in Advanced section) Clear count function is disabled.
Target Presets (PSET)
PSET function gives user ability to configure 50 preset target torque or target angle settings,
each with a target, minimum, maximum (over range) and batch count value. PSETs are stored
in non-volatile memory so that they are retained while power is off.
Note: After adding a Preset (see below), navigate between manual target torque, angle mode
and PSET screen by repeatedly pressing ENTER button. While PSET screen is displayed,
press UP/DOWN buttons to select additional configured PSETs.