Section
VI
-
TROUBLESHOOTING
(Cont'd)
PROBLEM
POSSIBLE
CAUSE
PROBABLE
SOLUTION
REFERENCES
6.6
Discharge
chute
rotates
freely.
Will
not
stay
fixed
In
desired
position.
a.
Debris
jammed
between
chute
rotation
detent
and
chute
mounting
ring.
b.
Compression
spring(s)
in
chute
rotation
detent
broken
(detent
is
not
locking
chute
mounting
ring
in
desired
position.
a.
Remove
debris
from
between
detent
and
chute
mounting
ring.
(Requires
partial
disassembly
of
auger
housing).
b.
Replace
rotation
detent
or
compression
springs
(requires
partial
disassembly
of
auger
housing).
Section
VII.
H.,
Pg.
16
Section
VII.
H..
Pg.
18
6.7
Excessive
noise
or
vibration
when
unit
is
In
operation.
a.
auger
flighting
torn
loose.
b.
Auger
blade(s)
bent
or
broken.
c.
Auger
shaft
bent
-
auger
hits
housing
when
rotating.
d.
Auger
shaft
bearings
worn
out.
e.
Top
housing
loose.
f.
Bottom
cover
loose.
a.
Repair/replace
auger
flighting.
b.
Repair/replace
auger.
(Requires
auger
housing
overhaul).
c.
Replace
auger
assembly
(Requires
auger
housing
overhaul).
d.
Replace
auger
bearings.
e.
Tighten
fasteners
(If
retaining
tabs
are
broken,
secure
top
housing
with
screws).
f.
Tighten
fasteners.
Section
VII.
D..
Pg.16
Section
VII.
E..
Pg.
16-17
Section
VII.
E..
Pg.
16-17
Section
VII.
F..
Pg.
17
Section
VII.
7.3.
A..
Pg.
15
g.
A
ll
mounting/retaining
hardware
is
loose.
Tighten
all
hardware.