UPS-ENTERPRISE
800-2000 VA
PRODUCT MANUAL

Questions and Answers

  • J
    Jacqueline MarksAug 10, 2025
    Why is the socomec ENT-RK10 battery backup time less than indicated?
    • D
      dakotaayalaAug 10, 2025
      There are several reasons why your Socomec UPS might not be providing the expected battery backup time. It could be due to the battery expansion switch being in the “OFF” position; in this case, turn the safety switch to “ON”. Another reason could be that the batteries are not fully charged; ensure you charge them for at least 8 hours consecutively.
  • B
    belljenniferAug 15, 2025
    What to do if the ALARM lamp is lit and the acoustic alarm sounds continuously on my socomec ENT-RK10 UPS?
    • P
      Paul LopezAug 15, 2025
      If the ALARM lamp is lit and the acoustic alarm is sounding continuously on your Socomec UPS, it could indicate overtemperature. Try to lower the ambient temperature.
  • K
    Kimberly BlackAug 19, 2025
    What to do if the OVERLOAD indicator lamp is lit on my socomec ENT-RK10 UPS?
    • J
      Julie GriffinAug 20, 2025
      If the OVERLOAD indicator lamp is lit on your Socomec UPS, it signifies an overload on the UPS output. Reduce the load connected to bring it within the nominal value.
  • E
    epetersonAug 25, 2025
    How to fix a socomec ENT-RK10 when the MAINS LED doesn't come on and the acoustic alarm sounds at intervals?
    • J
      Jeanne OlsonAug 26, 2025
      If the MAINS LED on your Socomec UPS does not illuminate and the acoustic alarm sounds intermittently, it could be due to several reasons. First, check if the main switch is properly inserted. If it is, the issue might be a missing mains voltage, in which case you should have an electrician check the mains. Finally, check the fuse on the input; if it's faulty, replace it with another one of the same type.
  • E
    Eddie HobbsAug 30, 2025
    How to troubleshoot no communication between socomec ENT-RK10 and PC?
    • S
      sgarciaAug 30, 2025
      If you're experiencing communication issues between your Socomec UPS and PC, there are a few things to check: * Ensure you are using the cable provided with the UPS. * Verify that other software applications aren't interfering with the PC interface. * Try changing the position of the data cable to avoid interference.
  • K
    Kayla MooreSep 3, 2025
    Why is the MAINS LED flashing on my socomec ENT-RK10 UPS?
    • T
      terri67Sep 4, 2025
      If the MAINS LED is flashing on your Socomec UPS, it indicates that the phase and neutral are inverted at the input. Disconnect the plug from the mains and re-insert it in the inverted position.

socomec ENT-RK10 Specifications

General IconGeneral
Product TypeUPS
Frequency50/60 Hz
Efficiency95%
Battery TypeLead-acid
CommunicationUSB
Operating Temperature0°C to 40°C