Figure 4-13 DC cable connection(3)
Step 4: Measure PV voltage of DC input with multimeter, verify DC input cable
polar and connect DC connector with inverter until hearing a slight sound indicated
connection succeed.
Figure 4-14 DC cable connection(4)
Figure 4-15 Use a multimeter to check the positive and negative electrodes
NotePlease use multimeter to make sure the PV array positive pole and
negative pole!
DealingIf need to remove the PV connector from inverter side, please use
the Removal Tool as below diagram, move the connector gently.
Before, moving the positive and negative connector, please make
sure “DC Switch” is on OFF position.