EasyManua.ls Logo

Sofar solar KTLX-G3 Series - Page 57

Sofar solar KTLX-G3 Series
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SOFAR 15~24KTLX-G3 User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd.
- 53 -
of Capital Airlines.
ID44
PvConfigErr
or
Input mode
incorrect
Please check the wiring of PV string,
whether each PV input is independent. If
the use method is not ruled out, please
contact the new energy customer service
of Capital Airlines.
ID45
CT
Disconnect
CT Fault
Please check the wiring of input, output
and communication according to the user's
manual. If the use method is not ruled out,
please contact the new energy customer
service of Capital Airlines.
ID46
ReversalC
onnection
Input reverse
connection
error
ID47
Reserved
Reserved
ID49
Reserved
Reserved
Ensure the installation position and
installation method meet the requirements
of this user manual.
Check whether the ambient temperature
of the installation position exceeds the
upper limit. If yes, improve ventilation to
decrease the temperature.
Check whether the inverter has dust and
dust, whether there are foreign matters
blocking the fan at the air inlet. If so, please
improve the ventilation and heat
dissipation of the environment. It is
recommended that the inverter should be
cleaned once every half a year.
ID50
TempFault_
HeatSink1
Heat sink1
over-temperat
ure protection
ID51
Reserved
Reserved
ID52
Reserved
Reserved
ID53
Reserved
Reserved
ID54
Reserved
Reserved
ID55
Reserved
Reserved
ID57
TempFault_
Env1
environment
temperature1
protection
ID58
Reserved
Reserved
ID59
TempFault_I
nv1
Model 1
over-temperat
ure protection
ID60
Reserved
Reserved

Related product manuals