OPERATION OF THE DEVICE
104 HYD 5K...20KTL-3PH
One Inverter need to be set as
Master (Primary), all other inverters
need to be set to Slave (Replica)
Set each inverter with an individual
parallel address. (It is an
independent number from Modbus
ID)
After changes, select “save” item to
save the settings
Resets the Bluetooth interface of
the inverter
This function is used to correct the
direction and grid phase
assignment of the connected CTs.
During CT Calibration, the inverter
must be connected to a battery and
the grid.
It is recommended to turn off the
load during calibration.
If calibration fails, check if the
battery can be charged/discharged
correctly
The inverter can be switched on,
switched off, set to standby or set
to normal operating mode, which
can be useful for installation or
maintenance work
Default setting: disabled