OPERATION OF THE DEVICE
64 SOFAR 1100...3300TL-G3
Activates or deactivates the
reactive power functions
Activates or deactivates the output
reduction function of the inverter
and sets the reduction rate
17. Feed-in power limitation
Activates or deactivates the feed-in
power function of the inverter and
sets the maximum feed-in power.
This function must be used
together with an external current
converter. Further information can
be found in chapter 4.5 of this
manual (RS485, current converter,
inverter logic interface connection)
Cyclical scanning of the IV curve in
order to find the global point of the
maximum output. Advisable in the
case of shaded solar generators.
The waiting time for switching on
and restarting following a mains
fault can be set here.
Activates or deactivates the meter
functions.
Activates or deactivates logical
interfaces. Further information can
be found in chapter 4.5 of this
manual (connection of the RS485-,
current converter- and inverter logic
interface).