Specifications
8
SPECIFICATIONS
Following are specifications for the iSTAR Pro 4U Rack Mount:
TABLE 3. Physical Specifications
Physical
Dimensions (H x W x D)
18 x 48 x 74 cm
(7 x 19 x 29 in)
Space Requirements 4U (standard rack units)
Environmental 0° to 50° C (32° to 122° F),
5 to 95% relative humidity, non-condensing
Weight 34 kg (74 lbs)
Misc. Alarms Fan failure, High temperature
Temperature Alarm 60° +/- 6°C, (140° +/- 10°F)
TABLE 4. Electrical Specifications
Electrical
Power Requirements 115 VAC, 60 Hz, ± 10%
Power 5A @600W
Heat Dissipation (Typical) 500 BTU/h
AC Input Circuit Breaker
Rating
15A
UPS Operation Battery charging included, with optional
17Ah batteries (5) provides nominal four hours
backup time; 48 hour recharge time
Memory and RTC Backup On-board rechargeable NimH batteries provide
minimum 12 hours retention of RAM and RTC
(Real Time Clock)
Max Lock Power (Total
Output)
16A
Individual Lock Current Limit 2.5A
Lock Relay Ratings 250,000 cycles