Chapter 6: LCD Status Screens and Setup Options
Firefighter Gateway Installation Guide MAN-01-00113-1.2
27
Wi-Fi
None
S_OK: The connection to the SolarEdge monitoring portal is successful (appears only if the inverter is
connected to the portal).
Status: Displays OK if the gateway established a successful connection and communication with the
specified server port/device (LAN, RS485, ZigBee transceiver or)
If the OK status is not displayed, an error has occurred.
xxx…:Eight-bit Ethernet Communication Connection Status: When Ethernet communication is used,
an additional row with a string of 1s and optionally 0s is displayed. 1 indicates OK, 0 indicates an
error. For a list of possible errors and how to troubleshoot them, refer to Troubleshooting Ethernet
Communication on page 39. The following is a list of bits description, ordered left-to-right:
Bit 1: The Ethernet link, physical Ethernet cable connection and WLAN link connection are all
OK.
Bit 2: The DHCP IP is OK. The IP was successfully obtained from DHCP (if set to static IP =1).
Bit 3: The ping gateway is OK. The ping to the local switch/router passed or the ping to APN was
OK.
Bit 4: The ping to google.com was OK.
Bit 5: The ping to server1 was OK.
Bit 6: The ping to server2 was OK.
Bit 7: The ping to server3 was OK.
Bit 8: Communication to the SolarEdge server is OK.
Error message: Refer to Troubleshooting Ethernet Communication on page 39.
IP Status
This window describes the Ethernet configuration: IP, Mask, TCP gateway and MAC address of the
gateway.
I P 1 9 2 . 1 6 8 . 2 . 1 1 9
M S K 2 5 5 . 2 5 5 . 2 5 5 . 0
G W 1 9 2 . 1 6 8 . 2 . 1
M A C 0 - 27- 02- 00- 39- 36
ZigBee Status
This window describes the ZigBee configuration:
PAN: X X X X X
C H : X X / X X X X R S S I : < L >
ID: X X X X X X X X X X X X X X X X
Z i g B e e R e a d y
PAN: The ZigBee transceiver pan ID.
CH: The ZigBee transceiver channel
RSSI: The receive signal strength of the neighboring ZigBee transceiver. L = low, M = medium, H =
high and - = no signal.
ID: The ZigBee transceiver ID.
ZigBee Ready: This field is shown only in devices with ZigBee router transceivers (slaves), in a multi-
point (MP) protocol configuration. If a ZigBee transceiver is not physically connected, a No ZigBee
message is displayed.