SE2200H SE3000H SE3500H SE3680H SE4000H SE5000H SE6000H Units
STANDARD COMPLIANCE
Safety IEC-62109-1/2, NZ3100
Grid Connection Standards
IEC61727, IEC62116, EN 50438, VDE-AR-N-4105, VDE 0126-1-1, UTE_C_15-712,
G83/2, G59/3, CEI-021, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1
Emissions IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part15 class B
RoHS Yes
INSTALLATION SPECIFICATIONS
AC Output- Cable Gland Diameter 9 - 16 mm
AC Supported Wire Cross Section 1 - 13 mm
2
DC Input
(1)
1 x MC4 pair 2 x MC4 pairs
Dimensions (HxWxD) 280 x 370 x 142 mm
Noise < 25 dBA
Weight 9.5 10.5 11 kg
Cooling Natural Convection
Operating Temperature Range
(2)
-40 to +60 °C
Protection Rating IP65 - Outdoor and Indoor
(1)
Connection of additional strings in parallel to a single input is allowed as long as the cumulative current does not exceed 45A.
(2)
Full power up to at least 50˚C / 122˚F. For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-
note.pdf
SolarEdge-Three Phase Inverter Specifications (Europe & APAC) MAN-01-00239-1.1
3