EasyManua.ls Logo

SolarEdge SE2500H - Page 77

SolarEdge SE2500H
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SE2200H SE3000H SE3500H SE3680H SE4000H SE5000H SE6000H Units
STANDARD COMPLIANCE
Safety IEC-62109-1/2, NZ3100
Grid Connection Standards
IEC61727, IEC62116, EN 50438, VDE-AR-N-4105, VDE 0126-1-1, UTE_C_15-712,
G83/2, G59/3, CEI-021, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1
Emissions IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part15 class B
RoHS Yes
INSTALLATION SPECIFICATIONS
AC Output- Cable Gland Diameter 9 - 16 mm
AC Supported Wire Cross Section 1 - 13 mm
2
DC Input
(1)
1 x MC4 pair 2 x MC4 pairs
Dimensions (HxWxD) 280 x 370 x 142 mm
Noise < 25 dBA
Weight 9.5 10.5 11 kg
Cooling Natural Convection
Operating Temperature Range
(2)
-40 to +60 °C
Protection Rating IP65 - Outdoor and Indoor
(1)
Connection of additional strings in parallel to a single input is allowed as long as the cumulative current does not exceed 45A.
(2)
Full power up to at least 50˚C / 122˚F. For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-
note.pdf