EasyManua.ls Logo

SolarEdge SE3K-RWB - Page 105

SolarEdge SE3K-RWB
111 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SE3K SE4K SE5K SE6K SE7K SE8K SE9K SE10K SE12.5K Unit
Operating
humidity – non
condensing
< 95 %
Cooling Fan (user replaceable)
Noise (typical)
< 50
(1)
dBA
Protection rating/
Environmental
category
IP65 - Outdoor and indoor
Maximum altitude 2000 m
Pollution degree
classification
(inside/outside)
2/3
Bracket mounted (bracket provided)
SE15K - SE33.3K
(2)
SE15K SE16K SE17K SE25K SE27.6K SE33.3K Unit
Output
Rated AC power
output
15000 16000 17000
25000
(3)
27600 33300 VA
Maximum AC power
output
15000 16000 17000 25000
6
27600 33300 VA
AC output voltage
line to line / line to
neutral (nominal)
380/ 220; 400/ 230 480/277 Vac
AC output voltage
range
184264.5 244-305 Vac
AC frequency 50/60 ± 5 Hz
Maximum continuous
output current (per
phase)
23 25.5 26 38 40
40
@277V
A
(1)
For inverters with a noise level suitable for residential environments refer to:
http://www.solaredge.com/files/pdfs/products/inverters/se-three-phase-indoor-
inverter-datasheet.pdf
(2)
The SE33.3Kmodel requires a medium voltage transformer.
(3)
24.99kVA in the UK
Three Phase System MAN-01-00507-4.2
104Technical Specifications - Three Phase Inverters (Europe &APAC)