Table of Contents

Questions and Answers

  • T
    Timothy BowmanAug 21, 2025
    What to do if the display of my SolarMax 8MT2 remains blank?
    • J
      Janice HowardAug 21, 2025
      If the display is blank, several factors could be at play. First, ensure that the DC disconnector Q1 is switched on. If it is, check if the irradiation is sufficient for operation; if not, wait. Also, verify that the PV generator strings are correctly connected. If these steps don't resolve the issue, and the PV generator connections are correct, it may indicate an internal failure.
  • J
    Jason RobbinsSep 3, 2025
    What should I do if my SolarMax 8MT2 displays 'L and N interchanged'?
    • K
      Kara FernandezSep 3, 2025
      This message indicates that a phase and the neutral conductor are incorrectly connected (interchanged). Connect the AC supplies correctly.
  • J
    Joanna RichardsonSep 1, 2025
    What does 'Burst error' mean on my SolarMax 8MT2?
    • J
      Justin GrahamSep 1, 2025
      A 'Burst error' indicates that the inverter disconnected from the grid five times or more on the same day. This warning is displayed for the remainder of the day. Check your plant’s status logger in MaxWeb xp (if present) or check the grid parameters. If this happens repeatedly, contact our SolarMax Service Centre.
  • S
    Scott AdamsAug 30, 2025
    What to do if SolarMax 8MT2 displays 'Mains error Mains error BP'?
    • J
      Joseph MooreAug 31, 2025
      This indicates that the grid has been switched off. If this problem continues to occur, contact the responsible grid operator.
  • V
    Victoria TurnerAug 29, 2025
    What to do if SolarMax 8MT2 Inverter shows 'Vac 10min too high (L1 L2 L3) Vac 10min too high BP (L1 L2 L3)'?
    • D
      David WallAug 29, 2025
      The maximum 10-minute average value of the mains voltage at the specified phase is too high. If this problem continues to occur, contact the responsible grid operator.
  • J
    James GordonAug 28, 2025
    What to do if my SolarMax 8MT2 displays 'Insulation fault DC Insulation fault DC BP'?
    • T
      tyler88Aug 28, 2025
      This indicates that the insulation resistance of the PV generator against earth is too low. Check the PV generator to resolve this issue.
  • T
    Thomas DavisAug 26, 2025
    What does it mean when my SolarMax 8MT2 displays 'Temperature limitation'?
    • W
      wrightjeffreyAug 26, 2025
      The feed-in power has been temporarily reduced to limit the temperature of the inverter. Clean the fan grids and improve ventilation in the operations room to resolve this.
  • P
    Paul CaldwellAug 25, 2025
    What to do if SolarMax Inverter shows 'No mains No mains BP'?
    • D
      Dr. Meredith CannonAug 25, 2025
      This message means that there is no mains voltage or the AC supply has been interrupted. You should check the AC supply to resolve this issue.
  • W
    Wesley EricksonAug 23, 2025
    What does it mean when my SolarMax 8MT2 shows 'Vdc too high (VDC3, VDC2, VDC1)'?
    • W
      wtaylorAug 23, 2025
      This message indicates that the DC input voltage at the specified DC connection is too high. Immediately switch off the DC disconnector Q1 and disconnect the PV generator from the inverter. Then, check the sizing of the PV generator.

Summary

Safety Instructions

Installation

Siting

Offers recommendations for selecting an appropriate installation location.

Installation

Details the physical mounting procedure for the inverter.

Electrical Connection

Covers all aspects of connecting the inverter electrically.

Commissioning

Switching On and Off

Provides step-by-step instructions for powering the inverter on and off.

Initial Start-up (Initial Setup)

Guides through the first-time configuration process upon startup.

Operation

Configuration

Details the adjustable operating parameters and advanced functions.

Settings

Covers communication parameters and monitoring functions.

Auto Test According to DK 5940

Data Communication

Configuration of the Data Communication Interfaces

Guides on setting up RS485 and Ethernet communication.

Operating Status

Troubleshooting

SolarMax Service Centre

Provides contact information for technical support.

Diagnosis & Measures

Details diagnostic procedures and corrective actions for failures.

General Troubleshooting

Lists common issues and their basic solutions.

Failures

Details specific error messages and failure conditions.

Specifications

Specifications

Presents detailed technical data for all inverter models.

Individual Country Settings

Lists configurable parameters specific to different countries.

Guarantee

SolarMax 8MT2 Specifications