b) Language
This inverter provides several languages for customer to select.
a) Date Time
This interface is for user to set the system date and time.
2013 ->06 <-06
10:19
Date time
English
Deutsch
Language
c) Ethernet
There are two modes to obtain IP address: static and DHCP.
User can set the information about ethernet such as IP address, subnet mask
number and default gateway number.
> IP Method
DHCP
Ethernet
d) Advanced
All the advance setting can be set here, such as battery, grid, EPS and so on.
“Advanced” is divided four parts: On-grid, Battery, Reset, User-define. And every
part has lower level parts.
Pls contact with your installer or factory for the installer password to enter.
On-grid
Battery
Reset
Advanced
d-1-1) Safety
User can set safety standard according to different countries and grid tied
stanndards.There are 8 standards to select. (May change without notice)
Item
7
1
2
3
4
5
6
8
Country
VDE 0126
ARN 4015
German
AS 4777
Australia
G83/2
UK
EN 50438_NL
Netherland
CEI 0-21
Italy
IEC61727_In
India
Standard
German
G59/3
UK
d-1-2) Power Factor ( For specific country if required by the local grid.)
There are 5 modes for selecting: Off , Under-Excited, Over-Excited, Curve, Q( u ).
Mode Comment
Off
Under-Excited PF value
Over-Excited PF value
Curve
Upper limit
Lower limit
Power Upper
Power Lower
PFLockInPoint ( CEI 0-21 only)
PFLockOutPoint ( CEI 0-21 only)
Q( u )
QuVupRate
QuVlowRate
-
( EN50438_NL only)
( EN50438_NL only)
Setting Setting
50
51
On-grid
(d-1)
Safety
(d-1-1)
Power Factor
(d-1-2)
Grid
(d-1-3)
Export Control
(d-1-4)
Self Test
(d-1-8)
DRM Function
(d-1-7)
P(U ) Function
(d-1-6)
Remote Control
(d-1-5)