EasyManuals Logo

SolaX Power X1-Fit-3.7C User Manual

SolaX Power X1-Fit-3.7C
37 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #35 background imageLoading...
Page #35 background image
Troubleshooting Troubleshooting
64
If your inverter's information panel is not displaying a Fault light, check the
following list to make sure that the present state of the installation allows
proper operation of the unit.
— Is the inverter located in a clean, dry, adequately ventilated place?
— Are the cables adequately sized and short enough?
— Are the input and output connections and wiring in good condition?
— Are the configurations settings correct for your particular installation?
— Are the display panel and the communications cable properly
connected and undamaged?
Contact SolaX Customer Service for further assistance. Please be prepared to
describe details of your system installation and provide model and serial number
of the unit.
65
BMS Lost
BMS Communication Lost
Check if the BMS cable is loose or broken.
Or seek help from us, if can not go back to normal state.
Inter Com Fault
Internal Communication Fault
Or seek help from us, if can not go back to normal state.
Turn off the battery and grid , reconnect them.
Fan Fault
Fan Fault
Or seek help from us, if can not go back to normal state.
Turn off the battery and grid , reconnect them.
AC HC T Fault
AC Current Sensor Fault
Or seek help from us, if can not go back to normal state.
Turn off the battery and grid , reconnect them.
Inv EEPROM Fault
Inverter EEPROM Fault
Or seek help from us, if can not go back to normal state.
Turn off the battery and grid , reconnect them.
RCD Fault
Residual Current Device Fault
Check the impedance of AC output.
Disconnect battery, reconnect it.
Or seek help from us, if can not go back to normal state.
EPS Relay Fault
EPS Relay Fault
Disconnect grid and battery, reconnect them.
Or seek help from us, if can not go back to normal state.
Grid Relay Fault
EPS Relay Fault
Disconnect grid and battery, reconnect them.
Or seek help from us, if can not go back to normal state.
OtherDevideFault
Other Devide Fault
Disconnect grid and battery, reconnect them.
Or seek help from us, if can not go back to normal state.
BMS_External_Err
Battery Fault-extarnal fault
Please contact battery suppiler.
BMS_Internal_Err
Battery Fault-intarnal fault
Please contact battery suppiler.
BMS_OverVoltage
Battery Fault-overvoltage fault
Please contact battery suppiler.
BMS_LowerVoltage
Battery Fault-undervoltage fault
Please contact battery suppiler.
BMS_ChargeOCP
Battery Fault-charge overcurrent fault
Please contact battery suppiler.
BMS_DischargeOCP
Battery Fault-discharge overcurrent fault
Please contact battery suppiler.
BMS_TemHigh
Battery Fault-over-temperature fault
Please contact battery suppiler.
BMS_CellImblance
Battery Fault-cell imbalance fault
Please contact battery suppiler.
BMS_TemLow
Battery Fault-under-temperature fault
Please contact battery suppiler.

Other manuals for SolaX Power X1-Fit-3.7C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolaX Power X1-Fit-3.7C and is the answer not in the manual?

SolaX Power X1-Fit-3.7C Specifications

General IconGeneral
BrandSolaX Power
ModelX1-Fit-3.7C
CategoryInverter
LanguageEnglish

Related product manuals