EasyManua.ls Logo

SolaX Power X3-Forth - User Manual

SolaX Power X3-Forth
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SolaX Power Network Technology (Zhe jiang) Co., Ltd.
X3-FORTH SERIES USER MANUAL
40kW - 150kW
Copyright Declaration
The copyright of this manual belongs to Solax Power Network Technology (Zhe jiang)
Co., Ltd. Any corporation or individual should not plagiarize, partitially or fully copy
(including software, etc.) , and no reproduction or distribution of it in any form or by
any means. All rights reserved. SolaX Power Network Technology (Zhe jiang) Co., Ltd.
reserves the right of final interpretation.
NO.288 Shizhu Road, Tonglu Economic Develpoment Zone, Tonglu City, Zhejiang
province, China.
Tel: +86 0571-56260011
E-mail: info@solaxpower.com
www.solax.power.com
614.00663.02

Other manuals for SolaX Power X3-Forth

Questions and Answers

  • D
    davidkellyAug 29, 2025
    What to do if SolaX Power Inverter displays GridVol_OP_10M error?
    • A
      Ashley SheltonAug 30, 2025
      If your SolaX Power Inverter displays a GridVol_OP_10M error, check whether the grid voltage is within the allowable range. Then, try to re run the inverter.
  • R
    Robert RussellAug 28, 2025
    What does GridFreq_UP1 mean on my SolaX Power Inverter and how to fix it?
    • H
      halloliviaAug 28, 2025
      If your SolaX Power Inverter displays a GridFreq_UP1 error, check whether the power grid frequency is within the allowable range. Then, try to re run the inverter.
  • M
    Mary Moore MDAug 27, 2025
    What does GridFreq_OP1 mean on my SolaX Power X3-Forth and how to fix it?
    • J
      Joshua JohnsonAug 27, 2025
      If your SolaX Power Inverter displays a GridFreq_OP1 error, check if the power grid frequency is within the allowable range. If it is, try restarting the inverter.
  • K
    kimberlymyersAug 27, 2025
    What does GridVol_UP1 mean on my SolaX Power X3-Forth and how to fix it?
    • A
      agibsonAug 27, 2025
      If your SolaX Power Inverter displays a GridVol_UP1 error, verify that the grid voltage is within the allowable range. If it is, try restarting the inverter.
  • S
    Sara NguyenAug 25, 2025
    What to do if SolaX Power X3-Forth Inverter displays GridVol_OP1 error?
    • A
      Antonio McculloughAug 26, 2025
      If your SolaX Power Inverter shows a GridVol_OP1 error, check whether the grid voltage is within the allowable range. Then, try to re run the inverter.
  • S
    Stacy RodriguezAug 25, 2025
    What should I do if my SolaX Power X3-Forth Inverter displays PV_VolHigh?
    • J
      Jeremy RussellAug 25, 2025
      If your SolaX Power Inverter shows a PV_VolHigh error, start by checking the PV voltage to ensure it's within the allowable range. If it is too high, reduce the number of PV modules in series to lower the PV voltage. If the problem persists, contact the installer.

SolaX Power X3-Forth Specifications

General IconGeneral
AC Frequency50/60 Hz
THD<3%
AC Output Voltage230Vac
Operating Temperature-25~+60°C
CoolingSmart Air Cooling
Cooling MethodSmart Air Cooling