10. Specifications10. Specifications
.54..55.
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
Operating frequency range (Hertz)
Max.efficiency
EU efficiency
Model
Dimensions
Weight
Topology
310W*563H*219D (mm)
1100
32+32
40+40
2/4
50/60
98.6%
98.0%
18.8kg
Transformerless
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
600
13000
14300
14300
19.8/18.8
S5-GR3P13K
THDi (at rated output power)
<2%
160...1000
Start-up voltage (Volts)
180
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
3/N/PE, 220/380, 230/400
Max. output current (Amps)
20.7
45...55 or 55...65
>0.99 (0.8 leading - 0.8 lagging)
Operating ambient temperature range
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
<60 dBA
Intelligent redundant fan-cooling
Self consumption (night)
<1 W
-25℃...+60℃
Relative humidity
0~100%
Grid connection standard
Display
Communication connections
Warranty Terms
LCD, 2×20 Z.
5 Years (Extend to 20 Years)
G98 or G99, VDE-AR-N 4105 / VDE V 0124,
EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019,
RD 1699 / RD 244 / UNE 206006 / UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1, TOR,
EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068,
IEC 61683, EN 50530
Safety/EMC standard
IEC 62109-1/-2, EN 61000-6-1/-2/-3/-4
DC connection
AC connection
MC4 connector
Quick connection plug
RS485, DO, DI, Optional: Wi-Fi, GPRS,USB*
3/(N)/PE~208/220/240
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
Operating frequency range (Hertz)
Max.efficiency
EU efficiency
Model
Dimensions
Weight
1100
2/2
50/60
98.0%
97.5%
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
330
5000
5500
5500
13.1
S5-GR3P5K-LV
THDi (at rated output power)
160...500
Start-up voltage (Volts)
180
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
310W*563H*219D (mm)
17.8kg
Max. output current (Amps)
14.4
>0.99 (0.8 leading - 0.8 lagging)
45...55 or 55...65
Topology
Transformerless
Operating ambient temperature range
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
<30 dBA
Natural convection
Self consumption (night)
-25℃...+60℃
Relative humidity
0~100%
16+16
20+20
<1 W
Grid connection standard
Display
Communication connections
Warranty Terms
LCD, 2×20 Z.
5 Years (Extend to 20 Years)
G98 or G99, VDE-AR-N 4105 / VDE V 0124,
EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019,
RD 1699 / RD 244 / UNE 206006 / UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1, TOR,
EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068,
IEC 61683, EN 50530
Safety/EMC standard
IEC 62109-1/-2, EN 61000-6-1/-2/-3/-4
DC connection
AC connection
MC4 connector
Quick connection plug
<2%
RS485, DO, DI, Optional: Wi-Fi, GPRS,USB*
IP66IP66
Optional USB* :only for the brazilian marketOptional USB* :only for the brazilian market
4000m4000m