Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Classification
No.of monitored strings per input port
No.of input ports per channel
No.of monitored channels
Rated channel curente (Amps)
Maximum current per input port (Amps)
Rated interruption current (Amps)
Rated grid voltage (Volts)
Rated output current (Amps)
Max. output current (Amps)
Power Factor (at rated output power)
Operating frequency range (Hertz)
Max.efficiency
EU efficiency
Model
Dimensions
Weight
310W*543H*180D (mm)
550
1/N/PE, 220
50/60
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
THDi (at rated output power)
<3%
90...500
Startup voltage (Volts)
90
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
18/32
20/40
2/3
AFCI Type: F-l-AFPE-1-3-1
1
3
1
18+32
18
18
97.7%
96.8%
330
7000
7000
7000
31.8
S6-GR1P7K2
13kg
>0.99 (0.8 leading - 0.8 lagging)
45...55 or 55...65
Topology
Operating ambient temperature range
Transformerless
-25℃...+60℃
Grid connection standard
EN 50549-1, IE C 62116, IEC 61727,
IEC60068, IEC 61683, EN 50530
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
<40 dBA
Natural convection
4000m
Relative humidity
0~100%
Display
Communication connections
Warranty Terms
LCD
5 Years (Extend to 20 Years)
Safety/EMC standard
DC connection
AC connection
MC4 connector
RS485, Optional: Wi-Fi, GPRS
Quick connection plug
Self consumption (night) <1 W(Night)
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
9. Specifications
.52. .53.
NOTE:
If the inverter displays any alarm message as listed in Table 8.1; please
turn off the inverter (refer to Section 5.2 to stop your inverter) and wait for 5
minutes before restarting it (refer to Section 5.1 to start your inverter). If the
failure persists, please contact your local distributor or the service center.
Please keep ready with you the following information before contacting us.
1. Serial number of Solis S6 Single Phase Inverter;
2. The distributor/dealer of Solis S6 Single Phase Inverter (if available);
3. Installation date.
4. The description of problem (i.e. the alarm message displayed on the LCD and the status
of the LED status indicator lights. Other readings obtained from the Information submenu
(refer to Section 6.2) will also be helpful.);
5. The PV array configuration (e.g. number of panels, capacity of panels, number of strings
, etc.);
6. Your contact details.
8. Trouble Shooting
Alarm Message
State 2 excursion
Failure description
The alarm happens when
G100 current limit is breached
due to sudden change of load
Solution
1.As required by G100 V2,the alarm needs
manual reset. Please clear the alarm using
the“Advanced Settings ->Internal EPM Set
-> G100Set->Clear Fault”setting in the
LCD/APP or remotely.
1.Please select the correct smart meter
type in inverter setting based on the smart
meter actually connected to the inverter.
Meter model fail
selected
MET_SEL_FAIL
DRM_CTL_Off
DRM function control the
inverter to be off state
1.Check if the DRM function is enabled.
This alarm indicates the DRM function
controls the inverter to stop. If this is not
expected, please disable the DRM function.
EPM-Hard Limit
The alarm happens when
EPM Hard Limit is breached
1.Check if the EPM-Hard Limit function is
enabled. This alarm indicates the EPM-
Hard Limit function controls the inverter to
stop. If this is not expected, please disable
the EPM-Hard Limit function.
Table 8.1 Fault message and description
31.8
IP66