EasyManua.ls Logo

Sony CDP-XE270 - Page 12

Sony CDP-XE270
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
CDP-XE270/XE370
Ver 1.1 2001.07
E-F Balance Check
Connection:
Procedure:
1. Connect an oscilloscpe to test point TP (TE1) and TP (VC) on
the BD board.
2. Turn the power on.
3. Put the disc (PATD-012) in to playback the number two track.
4. Press the [TIME] button. (The tracking servo and the sledding
servo are turned OFF)
5. Check the level B of the oscilliscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%
Traverse Waveform
6. Press the [TIME] button. (The tracking servo and sledding servo
are turned ON)
Confirm the C (DC voltage) is almost equal to the A (DC
voltage) is step 5.
Traverse Waveform
Checking Location: BD board
+
BD board
TP (TE1)
TP (VC)
oscilloscope
0V
B
level: 1.15
±
0.5 Vp-p
Center of
the waveform
A (DC
voltage)
0V
Tracking servo
Sled servo
ON
C (DC
voltage)
Tracking servo
Sled servo
OFF
Checking Location:
– BD BOARD (Conductor Side) –
TP
(RFDC)
TP
(FE1)
TP
(VC)
IC131
IC150
IC101
TP
(TE1)
TP
(RFAC)