6-16
EMG Hist Page 4
DVD 000000 Hour
7 00 00 00 00 00 00
00 00 00 00 00 00
8 00 00 00 00 00 00
00 00 00 00 00 00
Page UP: ↑
Exit: Return
Figure 24
The following hidden commands are available. Data clear can be
confirmed from the fact that the screen display changes.
Clearing laser ON hours
Press [DISPLAY] and [CLEAR] keys on the remote commander
(RMT-D107E/D107P) in this order.
Clearing emergency history
Press [TITLE] and [CLEAR] keys on the remote commander
(RMT-D107E/D107P) in this order.
After repair is finished, always clear emergency history data.
Clearing Syscon preset
Press [DVD MENU] and [CLEAR] keys on the remote commander
(RMT-D107E/D107P) in this order.
For EMG code, Mech mode, and Disc information of history dis-
play, see “Emergency code list”, “Mech mode list”, and “Disc type
list”.
6-8. Emergency History
With the initial menu displayed, press [4] key on the remote com-
mander (RMT-D107E/D107P), and the information on emergency
history of Drvcon and Syscon will be displayed. This information
is given over four pages, which can be changed over with [↑] and
[↓] keys. To return to the initial menu, press [RETURN] key.
EMG Hist Page 1
CD 000000 Hour
1 00 00 00 00 00 00
00 00 00 00 00 00
2 00 00 00 00 00 00
00 00 00 00 00 00
Page Down: ↓ Exit: Return
Figure 21
EMG Hist Page 2
DVD 000000 Hour
3 00 00 00 00 00 00
00 00 00 00 00 00
4 00 00 00 00 00 00
00 00 00 00 00 00
Page UP : ↑
Page Down: ↓ Exit: Return
Figure 22
EMG Hist Page 3
CD 000000 Hour
5 00 00 00 00 00 00
00 00 00 00 00 00
6 00 00 00 00 00 00
00 00 00 00 00 00
Page UP : ↑
Page Down : ↓ Exit: Return
Figure 23
N Page
N CD laser ON hours
N Emergency history
(latest)
N Emergency history (2)
N DVD laser ON hours
N Emergency history (3)
N Emergency history (4)
N Emergency history (5)
N Emergency history (6)
N Emergency history (7)
N Emergency history (8)