Chapter 3 Appendix
Remote control OPTION:
Mini-DIN 8-pin × 1
CONTROL UNIT:
D-sub 9-pin × 1
REMOTE 1:
D-sub 9-pin × 1 (with loop-
through output), RS-485 serial
interface
REMOTE 2:
D-sub 9-pin × 1
ISR:
D-sub 9-pin × 1
Video signal
Differential gain Less than 5% (for luminance from
0 to 100 cd/m
2
)
Differential phase Less than 5° (for luminance from
0 to 100 cd/m
2
)
Frequency response
50 Hz to 7 MHz, +1 dB/ –3 dB
DC restoration Back porch type
Black level fluctuation: less than
1% for 10 % to 90% APL input
signal variation.
Synchronization
AFC time constant
2 ms
Line pull range/line hold range
Greater than ±500 Hz
Vertical blanking time
Less than 1 ms
Horizontal blanking time
Less than 10 µs.
Picture performance
Normal scan 5% overscan of CRT effective
screen area (adjustable range
greater than ±15%)
Underscan 3% underscan of CRT effective
screen area (adjustable range
greater than ±15%)
Linearity Within a central area bounded by a
circle with a diameter equal to the
picture height, less than 1% of the
picture height, and outside the
same area, about 2% of the
picture height
Color temperature
D93, D65 (adjustable to other color
temperatures)
Convergence error
Within a central area bounded by a
circle with a diameter equal to the
picture height.
BVM-20G1U/20G1E/20G1A:
Less than 0.5 mm with a central
area bounded by a circle and less
than 0.9 mm at any other point.
BVM-14G1U/14G1E/14G1A/
14G5U/14G5E/14G5A:
Less than 0.4 mm with a central
area bounded by a circle and less
than 0.8 mm at any other point.
Standard luminescence
100 cd/m
2
(at standard 1 Vp-p
100% white signal)
Raster size stability
Less than 1% of picture height (at
100 cd/m
2
peak luminescence, 10
to 90% APL)
Scan delay Horizontal: Approx.
1
/
4
line
Vertical: Approx.
1
/
2
field
Resolution (at screen center, 100 cd/m
2
luminescence)
800 TV lines
Environmental conditions
Operating temperature
0°C to 35°C (32°F to 95°F)
Optimum operating temperature
20°C to 30°C (68°F to 86°F)
Operating humidity
0% to 90% (no condensation)
Accessories supplied
AC power cord (1)
Cord stopper (1)
Tally plate (1)
Operation manual (1)
Design and specifications are subject to change
without notice.
54
Chapter 3 Appendix
Specifications
Connection Cable Specifications for Color Temperature Probes
Special cables are required to connect color
temperature probes other than the Sony BKM-14L to
the monitor.
The following diagrams show specifications and pin
assignments for the required cables.
Connection cable for GRASEBY SLS 9400 probe
Modular connector Mini DIN 8-pin connector