EasyManua.ls Logo

Sony TRINITRON BVM-14G1A - Page 67

Sony TRINITRON BVM-14G1A
218 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-13
2. Adjustment Standard
2.1 Input the following signal to the G/Y input terminal of
the BK board to display it on the screen.
For BVM-14G1U/14G5U/20G1U: NTSC signal
For BVM-14G1A/14G1E/14G5A/14G5E/20G1A/
20G1E: PAL signal
2.2 Connect the RS-232C terminal of the CA-100 with the
OPTION terminal of the monitor using the cable shown
in “Required Tools and Measuring Instruments 5.”
(Refer to page 3-1).
2.3 Set the CA-100 as shown below, and connect the meas-
uring probe of the CA-100 at the center of the CRT
screen.
Display mode : xyY mode
Baud Rate : 9600
3. Select the SYSTEM/COLOR TEMP menu on the MAIN-
TENANCE menu.
4. Select D93 of COLOR TEMP, cover the CRT screen with
a black cloth, select FACTORY SET, and start automatic
adjustments.
5. Select D65 of COLOR TEMP, and select the PROBE/
MINOLTA CA-100 menu. After selecting D65, cover
the CRT screen with a black cloth, and select START to
start automatic operations.
6. Execute this adjustment only for BVM-14G1U/14G5U/
20G1U.
Select AUX of COLOR TEMP, and select the PROBE/
MINOLTA CA-100 menu.
After setting X = 0.331, Y = 0.346, LOWLIGHT = 2.7,
and HIGHLIGHT = 100, cover the CRT screen with a
black cloth, and select START to start automatic opera-
tions.
7. Select the SYSTEM/COLOR TEMP/COPY/OTHER
VALUE menu on the MAINTENANCE menu.
8. Select STD of COLOR TEMP, perform the following
“D65”, and copy the color temperature data to STD.
9. Select COLOR1 of COLOR TEMP, perform the follow-
ing “D93”, and copy the color temperature data to
COLOR1.
10. Select COLOR2 of COLOR TEMP, perform the follow-
ing step, and copy the color temperature data to
COLOR2.
For BVM-14G1U/14G5U/20G1U: Select AUX
For BVM-14G1A/14G1E/14G5A/14G5E/20G1A/
20G1E: Select D65
11. Execute this adjustment only for BVM-14G1A/14G1E/
14G5A/14G5E/20G1A/20G1E.
Select AUX of COLOR TEMP, perform the following
“D65”, and copy the color temperature data to AUX.