SECTION 4
ADVANCED OPERATION
4.1 Introduction
The DLM–E Series power supplies offer the following standard features:
Remote Programming of Output Voltage and Current Limit with 0–5V, 0–10V or 0–5k
ohms (Section 4.3)
Overvoltage Protection (OVP) with front panel control or 0–5, 0–10V or 0–5k ohms
programming (Section 4.4)
Programmable Shutdown with DC, or TTL compatible signals and contact closure
(Section 4.5)
Fault Signal, TTL compatible, 10 mA source. (Section 4.9)
Remote Monitoring of Status Indicators for thermal shutdown, OVP status, remote/local
programming mode, and voltage/current mode operation (Section 4.6)
Calibrated Readback Signals for output voltage and output current with selectable 0–5V
or 0–10V scales (Section 4.6)
Multiple Supply Configurations such as series, parallel, and split supply (Section 4.7)
Remote Voltage Sensing (Section 3.3)
Output Voltage Biasing (Section 4.7)
Accessing these features may require that you use one or more of the following procedures:
Using the front panel REMOTE/LOCAL programming switch.
Reconfiguring the rear panel J3 connector.
Making connections to the J3 connector.
Resetting rear panel DIP switch S1.
M362000-01 Rev E 4-1