SECTION 4
ADVANCED OPERATION
4.1 Introduction
The DLM–E Series power supplies offer the following standard features:
• Remote Programming of Output Voltage and Current Limit with 0–5V, 0–10V or 0–5k
ohms (Section 4.3)
• Overvoltage Protection (OVP) with front panel control or 0–5, 0–10V or 0–5k ohms
programming (Section 4.4)
• Programmable Shutdown with DC, or TTL compatible signals and contact closure
(Section 4.5)
• Fault Signal, TTL compatible, 10 mA source. (Section 4.9)
• Remote Monitoring of Status Indicators for thermal shutdown, OVP status, remote/local
programming mode, and voltage/current mode operation (Section 4.6)
• Calibrated Readback Signals for output voltage and output current with selectable 0–5V
or 0–10V scales (Section 4.6)
• Multiple Supply Configurations such as series, parallel, and split supply (Section 4.7)
• Remote Voltage Sensing (Section 3.3)
• Output Voltage Biasing (Section 4.7)
Accessing these features may require that you use one or more of the following procedures:
• Using the front panel REMOTE/LOCAL programming switch.
• Reconfiguring the rear panel J3 connector.
• Making connections to the J3 connector.
• Resetting rear panel DIP switch S1.
M362000-01 Rev E 4-1