SPECTRA SERIES 17
PART 4: ACCESS CODES
The Spectra Series control panels support the following 48 access codes:
4.1 ACCESS CODE LENGTH
Section [127] = System Options
Option [2] OFF = 6-Digit Access Codes
Option [2] ON = 4-Digit Access Codes (default)
All access codes can be set to lengths of either 4 or 6-digits. When the 4-digit option is selected, entering a 4-digit
code will allow access. Using the 6-digit option, entering 6 digits is required to allow access.
If the Access Code Length is changed from four digits to six digits when access codes have
already been programmed, the control panel will automatically add the last 2 digits by using the
first 2 digits. For example, if the access code is 1234 and you switch to 6 digits, the code will
become 123412. Be sure to verify the access codes after switching from 4-digit access codes to 6-
digit codes. When switching from six digits to four digits, the control panel will simply remove the
final two digits of the access code. For example, 123456 will become 1234.
4.2 INSTALLER CODE (Default: 000000)
The Installer Code is used to enter the control panel's programming mode (see page 15), which allows you to
program all the features, options and commands of the control panel. The Installer Code can be 4 or 6-digits in
length (see above) where each digit can be any value from 0-9. The Installer Code cannot be used to program the
Master or User Access Codes. To program the Installer Code press:
[ENTER]
+
[CURRENT INSTALLER CODE]
+ [281] + new 4 or 6-digit Installer Code
4.3 SYSTEM MASTER CODE (Default: 123456)
With the System Master Code a user can use any arming method and can program any User Access Code but not the
User Code Options described on page 17. The System Master Code can be 4 or 6 digits in length (see above), where
each digit can be any digit from 0 to 9. To change the System Master Code press:
[
ENTER
]
+
[
INSTALLER
CODE
]
+ [301] + new 4 or 6-digit System Master Code
4.4 USER CODE OPTIONS
Sections [302] to [348] - Feature Select Method: Options [1] to [7] on/off
The User Code Options define which arming methods each user can use to arm or disarm the system. Regardless
of these settings, all users can Regular Arm assigned partitions and all users except those with the Arm Only option
can disarm an assigned partition, regardless of how it is armed. Select one or more of the options described on the
following pages for each User Access Code, where sections [302] to [348] represent User Access Codes 002 to
048. For information on how User Access Codes are programmed, please refer to page 55.
INSTALLER CODE: Used to program all control panel settings except User Access Codes.
SYSTEM MASTER CODE (001) Provides full access. Arm and disarm using any method described in the User Code
Options on page 17 as well as program the User Access Codes.
MASTER CODE 1 (002): Permanently assigned to partition 1. Same as a regular User Code except it can
also program access codes for User Codes assigned to partition 1.
MASTER CODE 2 (003): Permanently assigned to partition 2. Same as a regular User Code except it can
program access codes for User Codes assigned to partition 2. If the system is not
partitioned Master Code 002 will be assigned to partition 1.
45 USER CODES (004-048): Can arm and disarm as per User Code Options in section 4.4.