as open in the keypad display but will not generate an alarm. When it occurs on in an armed system, the control
panel will follow the zone's Alarm Types setting (see page 24). This option is not permitted on UL systems.
[7] OFF / [8] ON - Trouble Only
When a tamper occurs on a wireless transmitter zone in a disarmed system, a Wireless Transmitter Supervision
Loss will appear in the keypads’ Trouble Display (see page 54) and the control panel will attempt to transmit the TX
Supervision Loss report code programmed in section [213]. When it occurs on in an armed system, the control
panel will follow the zone's Alarm Types setting (see page 24).
[7] ON / [8] OFF - Silent Alarm
When a tamper occurs on a wireless transmitter zone in a disarmed system, it functions the same as the "Trouble
Only" setting, but it will also generate a silent alarm. A silent alarm will not trigger any bells or sirens but the system
will have to be disarmed. In an armed system, the control panel will follow the zone's Alarm Types setting (see
page 24).
[7] ON / [8] ON - Audible Alarm
When a tamper occurs on a wireless transmitter zone in a disarmed system, it functions the same as the "Trouble
Only" setting, except it will also generate an audible alarm. In an armed system, the control panel will follow the
zone's Alarm Types setting (see page 24).
Functions only with the 1725, 1725EX, 1728 and 1728EX control panels.
10.13.1 RESTRICT ARMING ON SUPERVISION LOSS
Section [131] - Arming/Disarming Options
Option [6] OFF = Disabled (default)
Option [6] ON = Restrict Arming on Wireless Transmitter Supervision Loss
The control panel will not allow users to arm the system if it receives a Supervision Loss signal from the
Liberator
TM
Wireless Bus Module. Please note that the Wireless Transmitter Supervision Options must
be enabled. The control panel will not arm any partition until all Supervision Loss trouble conditions are
rectified.
10.13.2 SUPERVISION BYPASS OPTIONS
Section [131] - Arming/Disarming Options
Option [7] OFF = Generate Supervision Loss if Detected on a Bypassed Wireless Transmitter Zone (default)
Option [7] ON = No Supervision Loss if Detected on a Bypassed Wireless Transmitter Zone
When this feature is enabled, the Wireless Transmitter Supervision Options will follow the zone's bypass
definition. This means the control panel will not perform any action if a Supervision Loss occurs on a
bypassed zone. When this feature is disabled, the Wireless Transmitter Supervision Options will ignore the
bypass definition. This means the control panel will generate an incident as per Wireless Transmitter
Supervision Options if a supervision loss occurs on a bypassed zone.
10.14 REPROGRAM ALL EXPANSION MODULES
Section [750]
After removing an expansion module from the communication bus, the control panel keeps the module’s
programmed sections in memory. Therefore, if you add or replace a module you can re-program the module with the
settings saved in the control panel. To do so, enter section [750] and press
[
ENTER
]
. The keypad will emit 2 beeps
every second while downloading.