10.7 KEYPAD TAMPER SUPERVISION
Section [128]: General Options
Option [7] OFF = Keypad 1 Tamper Supervision Disabled (default)
Option [7] ON = Keypad 1 Tamper Supervision Enabled
Option [8] OFF = Keypad 2 Tamper Supervision Disabled (default)
Option [8] ON = Keypad 2 Tamper Supervision Enabled
The control panel can be programmed to monitor the on-board tamper status of one or two keypads in the system. If
Keypad 1 Tamper Supervision is enabled, the control panel will verify the on-board tamper status of a keypad whose
Keypad Zone Jumper (J1) is set to on. If Keypad 2 Tamper Supervision is enabled, the control panel will verify the
on-board tamper status of a keypad whose Keypad Zone Jumper (J1) is set to off.
Regardless of whether the keypad zones are being used or not, if more than one keypad has the
same Keypad Zone Jumper setting, Keypad Tamper Supervision will be lost. For example, if two of
the keypads in your system have the keypad zone jumper (J1) set to on, the control panel will not
recognize a Keypad 1 Tamper Supervision Failure.
If a keypad tamper occurs, the control panel can transmit the appropriate Zone Tamper report code (see page 33)
as originating from the zones specified by the Table 7. If the zone specified by the table below has been enabled,
the control panel will report the tamper as originating from the partition to which the zone is assigned. If the zone has
not been enabled, the control panel will send the Zone Tamper report code as originating from partition 1. A Tamper/
Zone Wiring Failure will also appear in the keypads’ Trouble Display (see page 54).
10.8 KEYPAD AUDIBLE TROUBLE WARNING
Section [127]: General Options
Option [3] OFF = Keypad Beep on Trouble Disabled
Option [3] ON = Keypad Beep on Trouble Enabled (default)
When enabled, the keypads will emit an intermittent beep tone whenever a trouble condition occurs in the system.
The intermittent beep tone will remain activated until the user enters the Trouble Display Mode by pressing the
[TBL]
or
[TRBL]
key. The intermittent beeps will be re-initialized whenever a new trouble occurs or the trouble has
restored and re-occurred.
10.9 INSTALLER QUICK FUNCTIONS KEYS
After entering the Installer Code, you can press a key to perform specific actions as described below.
10.9.1 I
NSTALLER
T
EST
M
ODE
[
ENTER
] + [
INSTALLER
CODE
] + [
TBL
]
OR
[
TRBL
]
The Installer Test Mode allows you to perform walk tests where the bell or siren will squawk and the
keypad will emit a confirmation beep to indicate opened zones. To enter this mode, simply enter the
Installer Code then press the
[
TBL
]
or
[
TRBL
]
key. The keypad will emit a confirmation beep. To disable
this mode, press the [TBL] key again. The keypad will emit a rejection beep.
10.9.2 TEST REPORT
[
ENTER
] + [
INSTALLER
CODE
] + [
MEM
]
Sends the Test Report report code programmed in section [211] to the central station.
Table 7: Zone Tamper Report Code for Keypad Tamper Supervision Failure
Keypad Tamper
1725EX 1725
1728EX 1728
1758EX 1758
NO ATZ WITH ATZ NO ATZ WITH ATZ
Keypad 1 Tamper Supervision = Zone 6 Zone 11 Zone 6 Zone 11
Keypad 2 Tamper Supervision = Zone 7 Zone 12 Zone 7 Zone 12