SPECTRA SERIES 43
10.9.3 CALL WINLOAD SOFTWARE
[
ENTER
] + [
INSTALLER
CODE
] + [
BYP
]
Refer to page 45.
10.9.4 CANCEL COMMUNICATION
[
ENTER
] + [
INSTALLER
CODE
] + [
STAY
]
Cancels all communication until the next reportable event.
10.9.5 ANSWER WINLOAD SOFTWARE
[
ENTER
] + [
INSTALLER
CODE
] + [
STAY
]
Refer to page 46.
10.10 ZONE EXPANSION MODULE SUPERVISION
Section [129]: General Options
Option [4] OFF = Zone Expansion Bus Module Supervision Disabled (default)
Option [4] ON = Zone Expansion Bus Module Supervision Enabled
By enabling this option, the control panel will supervise the Zone Expansion Module (SPC-ZX4 or ZX8) connected
to the Spectra bus. This means that whenever the Zone Expansion Module is disconnected or isn’t communicating
with the control panel, the control panel will attempt to transmit the Module Fault report code programmed in section
[210] and the Module Loss Failure will appear in the keypads’ Trouble Display (see page 54).
10.11 LIBERATOR WIRELESS BUS MODULE SUPERVISION
Section [129]: General Options
Option [5] OFF = Liberator Wireless Bus Module Supervision Disabled (default)
Option [5] ON = Liberator Wireless Bus Module Supervision Enabled
By enabling this option, the control panel will supervise the Liberator Wireless Bus Module (SPC-319) connected to
the Spectra bus. This means that whenever the Liberator Wireless Bus Module is disconnected or isn’t
communicating with the control panel, the control panel will attempt to transmit the Module Fault report code
programmed in section [210] and the Module Loss Failure will appear in the keypads’ Trouble Display (see
page 54).
Functions only with the 1725, 1725EX, 1728 and 1728EX control panels.
10.12 WIRELESS TRANSMITTER LOW BATTERY SUPERVISION
Section [129]: General Options
Option [6] OFF = Wireless Transmitter Low Battery Supervision Disabled (default)
Option [6] ON = Wireless Transmitter Low Battery Supervision Enabled
When the battery voltage of a Liberator wireless transmitter (motion detector or contact switch) has dropped to
below 6.5V., the Liberator Wireless Bus Module will send a message to the control panel. By enabling option [6] in
section [129], the control panel will attempt to transmit the Wireless Transmitter Low Battery report code
programmed in section [210] and the Wireless Transmitter Low Battery Failure will appear in the keypads’ Trouble
Display (see page 54).
Functions only with the 1725, 1725EX, 1728 and 1728EX control panels.
10.13 WIRELESS TRANSMITTER SUPERVISION OPTIONS
Section [132] - Zone Options
Please note that the Liberator Wireless Bus Module Supervision Option must be enabled (see page 47)
[7] OFF / [8] OFF - Supervision Failure Recognition Disabled (default)
When a tamper occurs on a wireless transmitter zone in a disarmed system, the control panel will display the zone