Maintenance Waukesha Cherry-Burrell
®
Brand C-Series Pump
01/2019 95-03008-IEC Page 21
6. Remove the casing and inspect the clamps and the casing for
damage or wear. Replace if necessary.
7. Push back on the impeller and position the retaining pin
(arrow) in the center of the stub shaft. This will allow the
impeller to be pulled off the stub shaft.
NOTE: C-2
14 shown. C-218 and C-328 impellers have 4
blades.
8. Remove the impeller
from the stub shaft.
9. Remove impeller retainer pin.
Figure 13 - Remove casing
Figure 14 - Push back on impeller
Figure 15 - Remove impeller
Figure 16 - Remove impeller pin