Maintenance Waukesha Cherry-Burrell
®
Brand C-Series Pump
Page 36 95-03008-IEC 01/2019
Remove Motor Adapter
NOTE: The shaft and motor adapter only need to be removed if
you are replacing the motor.
1. Loosen the shaft collar screws.
2. Carefully remove the stub shaft and shaft collar.
NOTE: Examine the
shaft sealing surfaces for nicks or scratches
which can cause excessive O-ring wear or leaking. Replace if
damaged.
3. Remove the motor adapter retaining bolts.
4. Remove the motor adapter.
NOTE: Motor
maintenance, repair and wiring are not covered in
this manual. For specific information, contact the motor
manufacturer.
Figure 72 - Loosen shaft collar screws
Figure 73 - Slide stub shaft off motor shaft
Figure 74 - Remove motor adapter bolts
Figure 75 - Remove motor adapter

Related product manuals