Maintenance Waukesha Cherry-Burrell
®
Brand C-Series Pump
Page 38 95-03008-IEC 01/2019
4. Remove both shaft collar screws.
5. Apply anti-seize to the threads. Reinstall the screws into the
shaft collar, leaving them loose.
6. Slide the shaft collar onto the stub shaft. Line up the slots of
the shaft collar with the slots on the stub shaft.
7. Slide the stub shaft onto the motor shaft.
Figure 79 - Remove shaft collar screws
Figure 80 - Apply anti-seize
Figure 81 - Slide shaft collar on stub shaft
Figure 82 - Slide stub shaft on motor shaft