EasyManua.ls Logo

ST STM32WB5MM-DK - CN7 TAG10 TAG-Connect

ST STM32WB5MM-DK
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8.4 CN7 TAG10 TAG-Connect
Section 7.1 presents the ST-LINK default debugging and programming tool. However, it is possible to use
another debugging and programming tool through the CN7 TAG-Connect in its TAG10 10pin version.
Figure 18. CN7 TAG-Connect pinout
Table 18. CN7 connector pinout
Pin number
Pin name Signal name STM32W5MMG pin Function
1 3V3_STLK 3V3 - Reference level
2 TAG_SWDIO SWDIO PA13 Serial wire data I/O
3 GND - - Ground
4 TAG_SWCLK SWCLK PA14 Serial wire clock
5 GND - - Ground
6 TAG_SWO SWO PB3 Serial wire output
7 NC - - -
8 NC - - -
9 NC - - -
10 TAG_NRST /Reset NRST Reset
If the TAG-Connect is used, it is very important to disable the embedded ST-LINK to avoid signal conflict between
this ST-LINK and the external tool. To disable the embedded ST-LINK, it is only necessary to set the STM32F103
in reset mode, with JP3 jumper ON.
UM2825
CN7 TAG10 TAG-Connect
UM2825 - Rev 1
page 26/42

Table of Contents

Related product manuals