bolts
Replace engine oil
(First time)
(Second time)
Clean engine oil filter ○(Replace if
necessary)
Replace air cleaner element (Service more frequently when used in
dusty areas)
(Replace)
Clean fuel filter
Check fuel injection pump
(Replace)
Check nozzle
Check fuel pipe ● (Replace if
necessary)
Adjust clearance of air intake/ exhaust
valves
(First time)
Grind air intake/exhaust valves
Replace piston ring
Check battery electrolyte Every month
Check carbon brush and slip ring
Check insulation resistance The generating set has been stored more than 10days ○
Note: “●” indicates that special tools are required.
9.2 Replace engine oil
Run the genset at zero load for 3 minutes and shut down
the engine. Unscrew the oil drain plug at the bottom of the
engine when the engine is still hot, drain off the oil
completely.
Tighten the plug after drain. Fill the fresh oil and to the
indicated level of oil dipstick.
9.3 Clean the engine oil filter
Cleaning interval Every 6 months or 500 hours
Replace the filter if necessary
Remove the oil filter element with oil filter wrench and
clean the Filter element.
Replace the element if it’s damaged.
Spread a thin oil film on the new oil filter sealing surface
and reinstall the filter. Clean the filter seat after the filter
is tightly screwed.
Ver. 3/Rev. 2; Data: 8.08.2022 48