5.1 Fitting the wheels (Figs. 4-5)
Fitthesuppliedwheelsasshowninfigures4&5.
5.1.1
Fitting the supporting foot
(only for
B 255/10/50, B 350/10/50, B480/10/50)
FitthesuppliedrubberstopperasshowninFig.6.
5.2 Fitting the quick-lock coupling for
tank pressure (ref. 13)
Screw the quick-lock coupling for unregulated tank
pressure (ref. 13) to the pressure vessel (ref. 2) as
showninFigures7and8.
5.3 Fitting the transport handle (ref. 9)
Screwthetransporthandle(ref.9)tothecompressor
asshowninFigures9and10.
5.4 Voltage
5.4.1 Single-phase version 230 V / 50 Hz
Thecompressorisequippedwithamainscablewith
shock-proofplug.Thiscanbeconnectedtoany230V
~50Hzshock-proofsocketwhichisprotectedbya16
Afuse.Beforeyouusethemachine,makesurethat
themainsvoltagecomplieswiththespecicationson
the rating plate. Longsupply cables,extensions, ca-
blereelsetc.causeadropinvoltageandcanimpede
motorstart-up.Inthecaseoflowtemperaturesbelow
+5°C,motorstart-upisjeopardizedasaresultofstiff-
ness.
5.4.1.1 Connection of the mains plug
(
electrical information for the BS plug
)
Important!
Thewiresinthemainsleadfittedtothisproductare
colouredinaccordancewiththecodeshowninfig.25.
● This product is double insulated and therefore
does not require a connection to earth.
● The3pinplugmustcomplytoBS1363/A.
● FusemustcomplytoBS1362.
If for any reason the 13 amp plug fitted to this product
requires replacement it must be wired in accordance
with the following instruction:
Do not connect the brown (live) or blue (neutral) to
the earth pin marked ‘E’ on the 3 pin plug.
Connect the Blue wire to the terminal marked Neutral
(N). Connect the Brown wire to the terminal marked
Live (L). Ensure that the outer insulation is gripped
by the cord grip and that the wires are not trapped
whenreplacingtheplugcover.Themainsleadonthis
productisfittedwitha13amp(BS1363/A)plug.A13
amp(BS1362)fusemustbefittedintheplug.
If in doubt consult a qualified electrician
Therearenouserserviceablepartsinsidethisproduct
except thosereferred toin the manual.Always refer
servicingtoqualifiedservicepersonnel.Neverremove
anypartofthecasingunlessqualifiedtodoso;thisunit
containsdangerousvoltages.
Warning!
For your protection if this product is to be used outdoors
it should not be exposed to rain or used in damp
locations.Donotplacetheproductondampsurfaces,
useaworkbenchifavailable.Foraddedprotectionuse
asuitableresidualcurrentdevice(R.C.D.)atthesocket
outlet.
Note: If the mains cable requires replacing it must be
replaced with an identical one and fitted by a
qualifiedperson.
5.4.2 3-phase version 400 V / 50 Hz
The compressor is equipped with a mains cable
witha16A CEEplug.This plug has a phase con-
verter.Beforeyouputtheequipmentintooperation,
check whether the motor rotates in the correct direc-
tion(seethedirectionarrowontheV-beltcover)by
switchingonthecompressorbriey.Ifthecompres-
sor motor rotates in the wrong direction, you must
correcttherotatingeldbyreversingthephasecon-
verterintheplug(useascrewdrivertodepressthe
phaseconverterslightlyandturnitthrough180°).
The motor is equipped with an overload switch. If
the compressor overloads, the overload switch will
switch off the equipment automatically to protect the
compressorfromoverheating.Iftheoverloadswitch
triggers,waitforthecompressortocooldown.
Long supply cables, extensions, cable reels etc.
causeadropinvoltageandcanimpedemotorstart-
up.
Inthecaseoflowtemperaturesbelow+5°C,motor
start-upisjeopardizedasaresultofstiffness.
5.5 On/Off switch (ref. 8)
5.5.1 Single-phase version (Fig. 2a)
Toswitchonthecompressor,pullouttheredknob(ref.
8).
Toswitchoffthecompressor,presstheredknob(ref.
8)inagain.

Table of Contents