EasyManua.ls Logo

Stanley B 255/10/50 - Belt and Filter Maintenance; Head Tension Rods Tightening; Storage; Storage Instructions

Stanley B 255/10/50
180 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
G
B
24
unscrewtheoildrainagescrew(ref.15)fromthecom-
pressorpump.Topreventtheoilfromrunningoutinan
uncontrolled manner, hold a small metal chute under
the opening and collect the oil in a vessel. If the oil
does not drain out completely, we recommend tilting
thecompressorslightly.
Dispose of the old oil at a drop-off point for old oil.
When the oil has drained out, re-t the oil drainage
screw(ref.15).Fillnewoilthroughtheoillleropening
(ref.14)untilitcomesuptotherequiredlevel.Then
replacetheoilsealingplug(ref.14).
6.6
Retensioning the V-belt (Figs.13-15)
Pull out the power plug and remove the safety guard
fortheV-belt.
Slackenthefourmotorxingscrews(A).
Shift the motor until the V-belt is tensioned to the
pointwhereitcanstillbedepressedbyapprox.1-2
cmatthelongestfreeposition.
Retighten themotorxingscrews(A)and retthe
safetyguardfortheV-belt.
6.7 Tightening of head tension rods
Checkthatallscrews(inparticularthoseofthehead
oftheunit)aretightlydrawnup(g.24).
Thecheckmustbecarriedoutpriortotherstcom-
pressorstarting.
TIGHTENING OF HEAD TENSION RODS
Nm
Min. torque
Nm
Max. torque
Screw M6 9 11
Screw M8 22 27
Screw M10 45 55
Screw M12 76 93
Screw M14 121 148
6.8Cleaningtheintakelter(ref.1)
Theintakelterpreventsdustanddirtbeingdrawnin.
Itisessentialtocleanthislterafteratleastevery100
hoursinservice.Acloggedintakelterwilldecreasethe
compressorsperformancedramatically.Undothetwo
Allenscrews(B).Youcanthenremovethelterfrom
the two halves of the plastic housing, tap it to remove
thedirt,blastitdownwithlow-pressurecompressedair
(approx.3bar)andre-insertit(Figures16-17-18).
6.9 Storage
Warning!
Pull the mains plug out of the socket and ventilate
the appliance and all connected pneumatic tools.
Switch off the compressor and make sure that it is
secured in such a way that it cannot be started up
again by any unauthorized person.
Warning!
Store the compressor only in a dry location which
is not accessible to unauthorized persons. Always
store upright, never tilted!
7. DISPOSAL AND RECYCLING
Theunitanditsaccessoriesaremadeofvarioustypes
ofmaterial,suchasmetalandplastic.Defectivecom-
ponents must be disposed of as special waste.Ask
yourdealeroryourlocalcouncil.