8. POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
Requesttheassistanceofaqualiedelectricianforoperationsonelectriccomponents(cables,motor,pressure
switch,electricpanel,etc).
FAULT CAUSE REMEDY
Air leak from the valve of the
pressureswitch.
Check valve does not perform its
function correctly due to wear or
dirtontheseal.
Unscrewthehex-shapedhead
of the check valve, clean the
housing and the special rubber
disk(replaceifworn).Re-
assembler and tighten carefully
().
Condensate drainage cock
open.
Close the condensate drainage
cock.
Rilsan hose not inserted
correctlyinpressureswitch.
Insert the Rilsan hose correctly
insidethepressureswitch.
Reductionofefciency,frequent
start-up.Lowpressurevalues.
Excessivelyhighconsumption.
Decrease the demand of
compressedair.
Leaksfromjointsand/orpipes. Changegaskets.
Cloggingofthesuctionlter.
Clean/replacethesuctionlter
().
Slippingofthebelt. Check belt tension
Themotorand/orthe
compressoroverheatirregularly.
Insufcientventilation. Improveambientconditions.
Closingofairducts.
Check and if necessary clean
theairlter.
Insufcientlubrication. Topuporchangeoil.
After an attempt to start the
compressor, it stops due to
tripping of the thermal cutout
causedbyforcingofthemotor.
Start-upwithheadofthe
compressorcharged.
Release the compressor head
by using the pressure switch
pushbutton.
Lowtemperature. Improveambientconditions.
Voltagetoolow.
Check that the mains voltage
matchesthatofthedataplate.
Eliminateanyextensions.
Incorrectorinsufcient
lubrication.
Check level, top up and if
necessarychangetheoil.
Inefcientelectrovalve. CalltheServiceCenter.