G
B
23
5.5.2 3-phase version (Fig. 2b)
To switch on the compressor, press the green knob
(ref.8.1).
Toswitchoffthecompressor,presstheredknob(ref.
8.2)inagain.
5.6
Adjusting the pressure (Figs.2a-2b)
● You can adjust the pressure on the pressure gauge
(ref.6)usingthepressureregulator(ref.7).
● The setpressurecan be takenfrom thequicklock
coupling(ref.5).
5.7 Setting the pressure switch
Thepressureswitchissetatthefactory.
Switch-onpressure: 8 bar
Switch-offpressure: 10 bar
6. CLEANING AND MAINTENANCE
Warning!
Pull the power plug before doing any cleaning and
maintenance work on the appliance.
Warning!
Wait until the compressor has completely cooled
down. Risk of burns!
Warning!
Always depressurize the tank before carrying out
any cleaning and maintenance work.
6.1 Cleaning
● Keep the safety devices free of dirt and dust as far
aspossible.Wipetheequipmentwithacleancloth
orblowitwithcompressedairatlowpressure.
● We recommend that you clean the appliance imme-
diatelyafteryouuseit.
● Clean the appliance regularly with a damp cloth and
somesoftsoap.Donotusecleaningagentsorsol-
vents;thesemaybeaggressivetotheplasticparts
intheappliance.Ensurethatnowatercangetinto
theinterioroftheappliance.
●
You must disconnect the hose and any spraying tools
fromthecompressorbeforecleaning.Donotclean
thecompressorwithwater,solventsorthelike.
6.2 Condensation water
Thecondensationwatermustbedrainedoffeachday
byopeningthedrainvalve(ref.11)(onthebottom of
thepressurevessel).
Warning!
The condensation water from the pressure vessel
will contain residual oil. Dispose of the condensa-
tion water in an environmentally compatible man-
ner at the appropriate collection point.
6.3 Safety valve (ref. 10)
Thesafetyvalvehasbeensetforthehighestpermit-
tedpressureofthepressurevessel.Itisprohibitedto
adjustthesafetyvalveorremoveitsseal.
6.4
Check the oil level at regular intervals
Placethecompressoronalevelandstraightsurface.
TheoillevelmustbebetweenthetwomarksMAXand
MINontheoillevelwindow(Fig.12/ref.16).
Changing the oil: Recommended hydraulic oil: SAE
15W/40oranalternativeofthesamequality.
It should be relled for the rst time after 100 hours
ofoperation.Thereaftertheoilshouldbedrainedand
relledafterevery300hoursinservice.
6.5 Changing the oil
Switch off the engine and pull the mains plug out of
the socket.After releasing any air pressure you can
MAINTENANCE RESUMPTIVE TABLE
FUNCTION
AFTER THE FIRST
100 HOURS
EVERY 100 HOURS
EVERY 300 HOURS
Cleaning of intake filter and/or
substitution of filtering element
●
Change of oil
● ●
Tightening of head tension rods
Thecheckmustbecarriedoutpriortothefirstcompressorstarting.
Draining tank condensate
Periodicallyandattheendofwork.
Checking the tension of the belts
Periodically.