5.5.2 3-phase version (Fig. 2b)
To switch on the compressor, press the green knob
(ref.8.1).
Toswitchoffthecompressor,presstheredknob(ref.
8.2)inagain.
5.6
Adjusting the pressure (Figs.2a-2b)
You can adjust the pressure on the pressure gauge
(ref.6)usingthepressureregulator(ref.7).
The setpressurecan be takenfrom thequicklock
coupling(ref.5).
5.7 Setting the pressure switch
Thepressureswitchissetatthefactory.
Switch-onpressure: 8 bar
Switch-offpressure: 10 bar
6. CLEANING AND MAINTENANCE
Warning!
Pull the power plug before doing any cleaning and
maintenance work on the appliance.
Warning!
Wait until the compressor has completely cooled
down. Risk of burns!
Warning!
Always depressurize the tank before carrying out
any cleaning and maintenance work.
6.1 Cleaning
Keep the safety devices free of dirt and dust as far
aspossible.Wipetheequipmentwithacleancloth
orblowitwithcompressedairatlowpressure.
We recommend that you clean the appliance imme-
diatelyafteryouuseit.
Clean the appliance regularly with a damp cloth and
somesoftsoap.Donotusecleaningagentsorsol-
vents;thesemaybeaggressivetotheplasticparts
intheappliance.Ensurethatnowatercangetinto
theinterioroftheappliance.
You must disconnect the hose and any spraying tools
fromthecompressorbeforecleaning.Donotclean
thecompressorwithwater,solventsorthelike.
6.2 Condensation water
Thecondensationwatermustbedrainedoffeachday
byopeningthedrainvalve(ref.11)(onthebottom of
thepressurevessel).
Warning!
The condensation water from the pressure vessel
will contain residual oil. Dispose of the condensa-
tion water in an environmentally compatible man-
ner at the appropriate collection point.
6.3 Safety valve (ref. 10)
Thesafetyvalvehasbeensetforthehighestpermit-
tedpressureofthepressurevessel.Itisprohibitedto
adjustthesafetyvalveorremoveitsseal.
6.4
Check the oil level at regular intervals
Placethecompressoronalevelandstraightsurface.
TheoillevelmustbebetweenthetwomarksMAXand
MINontheoillevelwindow(Fig.12/ref.16).
Changing the oil: Recommended hydraulic oil: SAE
15W/40oranalternativeofthesamequality.
It should be relled for the rst time after 100 hours
ofoperation.Thereaftertheoilshouldbedrainedand
relledafterevery300hoursinservice.
6.5 Changing the oil
Switch off the engine and pull the mains plug out of
the socket.After releasing any air pressure you can
MAINTENANCE RESUMPTIVE TABLE
FUNCTION
AFTER THE FIRST
100 HOURS
EVERY 100 HOURS
EVERY 300 HOURS
Cleaning of intake filter and/or
substitution of filtering element
Change of oil
Tightening of head tension rods
Thecheckmustbecarriedoutpriortothefirstcompressorstarting.
Draining tank condensate
Periodicallyandattheendofwork.
Checking the tension of the belts
Periodically.