EasyManua.ls Logo

Stanley Easikey 250 - Reader Wiring and Exit Switch; Detailed Reader Wiring Guide

Stanley Easikey 250
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Request to Exit (RTE)
A Request to Exit switch may be fitted on the secure side of the door. This should be a
normally-open switch that closes momentarily when pressed and released. Do not allow the
wiring for the RTE switch to be visible if the reader is removed from the wall.
Reader Wiring
If you do not intend to use the RTE switch then unscreened 4-core cable will be suitable;
otherwise use 6-core cable.
-
V
1 S1 R1 A1 +V1
+V SIG
V
CA -
V
A
B C
100 mA
Reader Wiring, including RTE
A Terminal Block B RTE C Reader
Use 7/0.2mm (0.22mm²) 4-core or 6-core unscreened cable.
Controller:
Channel 1 Channel 2
Colour: Reader:
+V1 +V2 Red +V
S1 S2 Blue SIG
R1 R2 White n/c
A1 A2 Yellow VCA
-V1 -V2 Black -V
Note: The reader outputs are set at 90mA. Stanley Security Products strongly recommend
that you fit a 100mA in-line fuse in the reader supply.
19