Power Supply Wiring
The cabinet already contains wiring from the power supply to the Easikey 250 controller and
to the battery wiring harness (although batteries are not supplied). Wiring is also in place
bringing the lock outputs to a terminal block below the Easikey 250 controller.
Cable Entry Options — Boxed Easikey 250
Two 40mm holes in the back of the cabinet for rear entry.
A 20mm knockout at the top and bottom of each side for surface mounted
conduit.
A 20mm × 40mm removable plastic insert at each side of the top and bottom
surfaces for surface mounted trunking. Each insert also has two 15mm
knockouts.
Cable Entry Options — Boxed Easikey 250 with Cutout
Two holes in the back of the cabinet for rear entry.
Two knockouts on the top suitable for use with 25 × 16mm trunking.
A 20mm knockout at the bottom of each side for surface mounted conduit.
Two 20mm knockouts on the bottom for surface mounted conduit.
Mains Power
Mains power, 240v AC, should be supplied to the controller through an illuminated,
unswitched spur. Use the following colour code:
Blue: Neutral
Green / Yellow: Earth
Brown: Live
Fuses
Location Type Rating
Mains Terminal Block 20mm glass, Slow Blow 1 Amp
Lock Supply * 20mm glass, Slow Blow 3.15 Amp
Battery Lead * 20mm glass, Slow Blow 3.15 Amp
Note: The Lock Supply and Battery fuses are located in a terminal block below the Easikey
250 controller.