Database Copy
This facility allows the contents of one Easikey 250’s memory to be copied to another
Easikey 250. The receiving Easikey 250 will have the contents of its memory completely
overwritten by the contents of the sending Easikey 250.
Note: You can copy from one Easikey 250 to another Easikey 250, or from an Easikey 99 to
an Easikey 250. You cannot copy from an Easikey 250 to an Easikey 99.
Connecting Two Easikey 250 Controllers for Database Copy
1. Remove power from both Easikey 250s.
(Only one Easikey 250 needs to be powered during the copy.)
2. Connect Reader terminal 2 of each Easikey 250 with the following cable:
Sending Controller Receiving Controller
-V2
————————
-V2
S2
————————
A2
A2
————————
S2
+V2
————————
+V2
Use 0.22mm² reader cable for a distance less than 10m.